Radiation Safety. Amplified.
Join us on Linkedin
Follow us on YouTube
Subscribe to our Blog

Argos TPS Family of Gasless Contamination Monitors

Products in this category

Argos "PB" Whole Body Contamination Monitors for ß Detection

Argos "PB" Whole Body Contamination Monitors for ß Detection

Description

The CANBERRA Argos-PB line of Whole Body Contamination Monitors provides user-friendly operation with thorough and reliable detection of external contamination on personnel working in nuclear environments. Both the Argos-5PB and Argos-3PB monitors feature our most advanced gasless, Thin Plastic Scintillator (TPS) detectors, optimized for the best possible beta response (along with minimizing the gamma response).

Until recently, the elimination of counting gas has been the only advantage of using of plastic scintillation detectors over traditional gas flow detectors in whole body monitors. The sacrifice for this advantage was in detector performance (low efficiency, bad uniformity) leading to longer count times. CANBERRA has successfully addressed the challenges of this gasless detector technology, minimizing the trade-off between operating costs and performance.

The Argos-3/-5PB gasless monitors offer the same industry-best contour geometry as the Argos-3/-5AB gas flow monitors. The need for counting gas is eliminated by using scintillation detectors with an embedded PMT to minimize dead space between detectors. This arrangement provides optimal contour geometry and coverage for the occupant.

All Argos monitors use a sophisticated "fast following" background trending and release-limit algorithm to provide the best performance in a stable or varying radiation field.

With CANBERRA WebRemote™ software, an easy-to-use touch screen graphical user interface for industrial PC-based operation, results in improved health physics programs, better tracking of contamination and faster, more thorough personnel throughput at boundary points.

Excellent detector protection, modularity of components, and extensive diagnostics result in direct reductions in maintenance, repair, and operation costs.

Argos

Features

  • Fast personnel throughput with exceptional coverage due to optimized counting geometry and shielding
  • The Argos-5PB provides the ultimate in (two-step) contoured body coverage
  • The Argos-3PB provides contoured body coverage with strategic positioning of detectors in an economical configuration
  • Similar performance to gas flow proportional detectors (efficiency, background)
  • Optimization of detector operating parameters may be done on an individual basis for enhanced performance
  • Simultaneous monitoring of both sides of the hand with moveable detector for enhanced beta sensitivity
  • Minimal gaps between detectors for smaller dead zones
  • Space-saving design minimizes overall clearance requirements and allows for easy maintenance access from front and side of the unit
  • WebRemote enabled: ergonomic and easy-to-use touch screen graphical user interface; accessible locally or via PC/tablet web browser
  • Windows® 7 Embedded operating system with LAN capability and USB ports
  • Same "industry-best" software and serial bus electronics across CANBERRA Argos-TPS/AB, Cronos®-1/4 /11, Sirius™-5 and GEM™-5 family; no re-training needed
  • Compliant with IEC61098 Standard requirements
  • Algorithm based on Gaussian or Bayesian statistics (compliant with the ISO 11929:2010 Standard requirements)
Argos "PBG" Whole Body Contamination Monitors for ß/γ Detection

Argos "PBG" Whole Body Contamination Monitors for ß/γ Detection

Description

The CANBERRA Argos-PBG family of Whole Body Surface Contamination Monitors provides the ultimate user-friendly operation with thorough and reliable detection of external contamination on personnel working in nuclear environments. Both Argos-5PBG and Argos-3PBG monitors feature our most advanced gasless, Thin Plastic Scintillator (TPS) detectors optimized for the best possible beta/gamma response.

Until recently, the elimination of counting gas has been the only advantage of using of plastic scintillation detectors over traditional gas flow detectors in whole body monitors. The sacrifice for this advantage was in detector performance (low efficiency, bad uniformity) leading to longer count times. CANBERRA has successfully addressed the challenges of this gasless detector technology, minimizing the trade-off between operating costs and performance.

The Argos-3/-5PBG gasless monitors offer the same industry-best contour geometry as the Argos-3/-5AB gas flow monitors. The need for counting gas is eliminated by using scintillation detectors with an embedded PMT to minimize dead space between detectors. This arrangement provides optimal contour geometry and coverage for the occupant.

All Argos monitors use a sophisticated "fast following" background trending and release-limit algorithm to provide the best performance in a stable or varying radiation field.

With CANBERRA WebRemote™ software, an easy-to-use touch screen graphical user interface for industrial PC-based operation, results in improved health physics programs, better tracking of contamination and faster, more thorough personnel throughput at boundary points.

Excellent detector protection, modularity of components, and extensive diagnostics result in direct reductions in maintenance, repair, and operation costs.

Argos “PBG” Whole Body Contamination Monitors for ß/γ Detection

Features

  • The first gasless beta /gamma Whole Body Contamination Monitor in the market
  • Fast personnel throughput with exceptional coverage due to optimized counting geometry and shielding
  • The Argos-5PBG provides the ultimate in (two-step) contoured body coverage
  • The Argos-3PBG provides contoured body coverage with strategic positioning of detectors in an economical configuration
  • Beta and gamma response on each detector. Improved gamma efficiency, coverage and finer localization of contamination – suited for high background environments
  • Includes a Front Curtain with 60 field-installable lead ingot bricks to provide shielding
  • Space-saving design minimizes overall clearance requirements and allows for easy maintenance access from front and side of the unit
  • WebRemote enabled: ergonomic and easy-to-use touch screen graphical user interface; accessible locally or via PC/tablet web browser
  • Windows® 7 Embedded operating system with LAN capability and USB ports
  • Same "industry-best" software and serial bus electronics across CANBERRA Argos-TPS/AB, Cronos®-1/4 /11, Sirius™-5 and GEM™-5 family; no re-training needed
  • Compliant with IEC61098 Standard requirements
  • Algorithm based on Gaussian or Bayesian statistics (compliant with the ISO 11929:2010 Standard requirements)
Argos "PAB" Whole Body Contamination Monitors for α/β Detection

Argos "PAB" Whole Body Contamination Monitors for α/β Detection

Description

The CANBERRA Argos-PAB family of Whole Body Surface Contamination Monitors provides the ultimate user-friendly operation with thorough and reliable detection of external contamination on personnel working in nuclear environments. The Argos-5 PAB and Argos-3 PAB feature our most advanced gasless, Thin Plastic Scintillator (TPS) detectors optimized for the best possible alpha/beta response (along with minimizing the gamma response).

Until recently, the elimination of counting gas has been the only advantage of using of plastic scintillation detectors over traditional gas flow detectors in whole body monitors. The sacrifice for this advantage was in detector performance (low efficiency, bad uniformity) leading to longer count times. CANBERRA has successfully addressed the challenges of this gasless detector technology, minimizing the trade-off between operating costs and performance.

The Argos-3/-5PAB gasless monitors offer the same industry-best contour geometry as the Argos-3/-5AB gas flow monitors. The need for counting gas is eliminated by using scintillation detectors with an embedded PMT to minimize dead space between detectors. This arrangement provides optimal contour geometry and coverage for the occupant.

All Argos monitors use a sophisticated "fast following" background trending and release-limit algorithm to provide the best performance in a stable or varying radiation field.

With CANBERRA WebRemote™ software, an easy-to-use touch screen graphical user interface for industrial PC-based operation, results in improved health physics programs, better tracking of contamination and faster, more thorough personnel throughput at boundary points.

Excellent detector protection, modularity of components, and extensive diagnostics result in direct reductions in maintenance, repair, and operation costs.

Argos “PAB” Whole Body Contamination Monitors for ß/γ Detection

Features

  • The first gasless alpha/beta Whole Body Contamination Monitor
  • Fast personnel throughput with exceptional coverage due to optimized counting geometry and shielding
  • The Argos-5PAB provides the ultimate in (two-step) contoured body coverage
  • The Argos-3PAB provides contoured body coverage with strategic positioning of detectors in an economical configuration
  • Alpha and Beta discrimination capability for unequivocal contamination status
  • Space-saving design minimizes overall clearance requirements and allows for easy maintenance access from front and side of the unit
  • WebRemote enabled: ergonomic and easy-to-use touch screen graphical user interface; accessible locally or via PC/tablet web browser
  • Windows® 7 Embedded operating system with LAN capability and USB ports
  • Same "industry-best" software and serial bus electronics across CANBERRA Argos-TPS/AB, Cronos®-1/4 /11, Sirius™-5 and GEM™-5 family; no re-training needed
  • Compliant with IEC61098 Standard requirements
  • Algorithm based on Gaussian or Bayesian statistics (compliant with the ISO 11929:2010 Standard requirements)